Part 3: Fan Troubleshooting Guide - Detroit
Posted by Kustom Truck Parts on 9th Feb 2026
Fan Troubleshooting Guide: Part 3 – Detroit Engines
A properly functioning cooling fan is crucial for Detroit engine performance and longevity in heavy-duty trucks. Whether your fan is running constantly (draining power and fuel) or failing to engage (risking overheating), systematic troubleshooting will pinpoint the problem efficiently.
This is the final installment in our three-part Fan Troubleshooting Guide series. Today, we’re covering Detroit engines (DDEC 3, 4, and 5). Part 1 addressed Caterpillar, and Part 2 handled Cummins. Follow these steps in order for the most accurate diagnosis.
1. Verify the Fan Solenoid Type
Always start here: Confirm the correct fan solenoid configuration. The key is understanding whether your fan clutch requires air pressure to engage/lock up the fan hub or air pressure to release/disengage it.
- Air to engage/lock-up: Requires a normally OPEN fan solenoid.
- Air to release: Requires a normally CLOSED fan solenoid.
Note: This is the only factor determining the proper solenoid—regardless of current fan behavior.
If the solenoid is incorrect:
- Some models allow re-plumbing by swapping the air supply line and exhaust port to reverse the state.
- Others cannot be re-plumbed and require full replacement with the correct solenoid. At Kustom Truck Parts, we stock both normally open and normally closed fan solenoids to get you back on the road quickly. Shop our selection of fan solenoids here.
Once confirmed correct, proceed to Step 2.
2. Check Fan Solenoid Electrical Connections
Next, inspect the electrical side. Detroit controls the fan with a ground output signal from the ECM:
- ECM sends ground to the solenoid → Fan OFF (disengaged)
- ECM removes ground → Fan ON (engaged)
Use a multimeter on the two leads at the solenoid:
- One lead should have constant key-switched +12V power.
- The other lead will show ground (or not) based on ECM command.
Important: This logic holds only if Step 1 solenoid type is correct.
- No +12V key-switched power? Trace it and connect to a proper key-switched +12V source.
- Power good, but no ground? Check continuity on the ground lead to the ECM output pin:
- Detroit DDEC3/4: Pin #A2
- Detroit DDEC5: Pin #4
- No continuity? Trace and repair the wiring.
- Good continuity and power? Proceed to Step 3.
3. Verify ECM Input Status
Now confirm the four inputs that dictate fan operation. You'll need diagnostic software (Detroit Diesel Diagnostic Link, ProLink, etc.) to monitor live status.
Connect and navigate to the status/input-output section. Monitor:
- Cooling fan output
- Four control inputs: Coolant temperature, Intake/manifold temperature, A/C high pressure switch, Fan override switch
Check the three common inputs first:
- Coolant Temperature → Triggers fan ON above 200°F. Verify reading is accurate and below threshold. Fix sensor or wiring if inaccurate.
- Intake/Manifold Temperature → Triggers fan ON above 110°F. Verify accuracy.
Tip: After shutdown, heat soak can cause high readings. Briefly run the engine to purge hot air for a true value. - A/C High Pressure Switch → Normally CLOSED circuit (constant ground = no fan needed). Opens at high pressure → removes ground → signals fan ON.
Test: Unplug/replug the switch while watching ECM status—it should toggle. Confirm one connector lead has solid ground. Simulate closed circuit by jumping the two pins.
Fan Override Switch (Manual Fan Switch):
- Detroit DDEC3, 4, and 5: Analog input only.
DDEC3/4 use programmable multifunction inputs—Kustom Truck harnesses follow Detroit standard using Pin #E1.
DDEC5 uses dedicated Pin #V49.
Toggle switch while monitoring the input parameter—it should change state.
If no change: Verify the input pin is correctly programmed for fan override, then trace the analog circuit from the dash switch to the ECM pin.
All inputs correct? Proceed to Step 4.
4. Confirm ECM Output Status
Final check: With all inputs below thresholds and correct (Coolant <200°F, Intake <110°F, A/C switch providing ground, Override OPEN), the ECM should command fan OFF.
In Detroit Diesel Diagnostic Link:
- Look for the “fan clutch” output parameter in the input/output configuration screen.
When status shows GROUNDED → ECM output active (ground supplied) → fan should be OFF.
When status shows OPEN → ECM output open (no ground) → fan should be ON.
- Matches expected? System working correctly.
- Doesn't match? Re-trace from Step 1. Persistent issues may require a test ECM.
Following this guide methodically resolves most Detroit fan issues. This concludes our three-part Fan Troubleshooting Guide series—thanks for following along!
Happy wrenching!
—The Kustom Truck Parts Team
Ready to Repower Your Truck? Call Now: 1-888-564-8890
Mon–Fri 7AM–4PM PST | Speak with a repower specialist